Intel® Rapid Storage Technology 11.0.0.1024 Beta Version Release Notes
29 September 2011
DISCLAIMER: Information in this document is provided in connection with Intel products. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty relating to sale and/or use of Intel products, including liability or warranties relating to fitness for a particular purpose, merchantability or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, lifesaving, or life-sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without notice.Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.
* Other names and brands may be claimed as the property of others.
Copyright © Intel Corporation 2000-2011
Supported Operating Systems
Microsoft Windows 7*
Microsoft Windows 7 x64 Edition*
Microsoft Windows Vista* (not supported on Panther Point platforms)
Microsoft Windows Vista x64 Edition* (not supported on Panther Point platforms)
Microsoft Windows XP Home Edition*
Microsoft Windows XP Professional*
Microsoft Windows XP x64 EditionMicrosoft Windows Server 2008* ++
Microsoft Windows Server 2008 x64 Edition*++
Microsoft Windows Server 2008 R2 x64* ++
Microsoft Windows Server 2003* ++
Microsoft Windows Server 2003 x64 Edition*++Microsoft Windows Media Center Edition*
++ Not available on mobile platforms
Revision History
Date
Driver Revision
Build Number
29 September 2011
11.0.0.1024 Beta
1024
14 July 2011
11.0.0.1015 Alpha
1015
25 May 2011
11.0.0.1009 Alpha1
1009
Notes:
1. Known Issue is defined as a potential RST issue that has been replicated internally by the Rapid Storage Technology team but has not been root caused to be an RST defect.
2. Microsoft Windows Vista (32 & 64-bit) is not supported on Panther Point based platforms.
3. The RAID OROM version for this release is 11.0.0.1204, the driver and user interface version is 11.0.0.1024.
4. This release includes both the RAIDCFG32 & RAIDCFG64 utilities which are contained in the RAIDcmd utility component of this kit. Contact your RST representative with any questions.
5. When an ODD is in the Zero Power state, some ODDs may disappear when a hardware re-scan is initiated via the Windows Device Manager. A second hardware re-scan conducted before the Zero Power Idle Timeout value is reached (default is 60s) will return the drive to an OS visible state. This behavior is believed to be related to the length of time an ODD requires to become ready during power on from the zero-power state.
6. Microsoft* .NET Framework 3.0 is required to be installed on the system in order for the Intel® Rapid Storage Technology User Interface to install. Note that not all Microsoft* Operating Systems have .NET 3.0 installed by default. Refer to the Microsoft* website for details.
7. A Vista OS Installation using a Matrix RAID Array on a system with a 9.5 or newer OROM requires the user to F6 a 9.5 or newer driver.
8. Possible issue where RST is slow to start on Windows XP or Vista with .NET 3.0
Issue description: Under certain network conditions, on systems with .NET 3.0, the RST application and notification icon (a.k.a. tray icon) may take about a minute to start.
Resolution: Contact Microsoft* to receive the hot fix described by KB article 936707 or upgrade to .NET 3.5.
9. Possible Issue regarding File writes on Windows XP with Service Pack 2
Issue description: System hangs, ERROR_NO_SYSTEM_RESOURCES or ERROR_NOT_ENOUGH_QUOTA observed when writing large numbers of files on Windows XP with Service Pack 2.
Resolution: Contact Microsoft* to receive the hot fix described by KB article 888413.
Resolved Issues
Resolved Issues in 11.0.0.1024 Beta |
|
||
Reference No |
Description |
Affected OS's |
|
3235441 |
WinDVD 10 playback of CPRM protected
content will be denied after installing the Intel® Rapid Storage Technology
driver |
Win7-64 |
|
3235696 |
OS
crashes when running "Scan for and attempt recovery of bad sectors"
on a RAID volume |
Win7, Win7-64 |
|
3235317 |
Degrading
an Accelerated (Max mode) RAID5 Volume with 16 KB Strip Size sporadically
causes catastrophic Data Loss upon Reboot |
N/A |
|
3235387 |
SUT
halts at the 1st cycle while running specific utility in DOS with a RAID5
volume |
N/A |
|
3235580 |
SUT
cannot boot to degraded bootable RAID5 volume after one HDD is removed from
the RAID5 volume |
N/A |
|
3235494 |
Legacy
OROM does not handle Segment Wrapping of Data Buffers for int13 I/O. Always
returns NOT_SUPPORTED |
N/A |
|
3235456 |
RcfgSata.exe
does not allow enabling acceleration if RAID0 is disabled via BCFS |
N/A |
|
3235061 |
RCfgSata.txt
in RST 11.0 - missing parameter documentation |
N/A |
|
3006447 |
Changing
contrast settings eliminates UI info |
WinXP-64 |
|
3235422 |
Unbundling
of the OS sporadically results in 0x7E BSOD with Smart Response Technology
enabled |
Win7-64 |
|
3235548 |
Disable
Acceleration twice on an Accelerated single disk RAID0 OS volume during a
data migration then Enable again induces 0x7A BSOD |
Win7-64 |
|
3007204 |
Naming
Volume "Array_0000" makes it completely disappear in RST UI |
Win7 |
|
3234687 |
Online
Help: Volume Requirements table is missing Cougar Point in the
"Controller Support" column |
WinXP-64 |
|
3234887 |
System
report heading does not match in saved text file |
Win7-64, WinXP |
|
3235067 |
Smart
Response Technology not honoring user's power plan |
Win7-64 |
|
3235253 |
Device
detection failure after resuming from S3 |
Win7-64 |
|
3235380 |
Volume
can't be renamed when other volume in the Matrix RAID is in
verification/rebuild/initialization state |
Win7, Win7-64 |
|
3235553 |
Unknown
controller displayed in the RST UI |
Win7-64 |
|
3235558 |
Disassociating
help icon hover text string incorrect |
Win7 |
|
3235572 |
Optical
Disk Drives reported as Type: Hard disk, in RST UI System Report |
Win7 |
|
3235622 |
Readme
needs update - Remove obsolete Intel(R) ICH9R/DO/DH SATA AHCI Controller |
Vista, WinXP,
Win7 |
|
3235149 |
Reset
disk to normal button is not shown in UI |
Vista, Vista-64 |
|
3235279 |
Accelerated
pass-through data disk: Error message pop-up in UI when trying to use a
different SSD to Accelerate the disk after auto-transition Enhanced mode to OFF
due to missing Cache SSD |
Win7,
Win7-64 |
|
3235305 |
Wrong
device name on Chief River |
Vista |
|
3235378 |
BSOD
during Bad Block tests on XP 32 Rose City system |
WinXP |
|
3235129 |
0x7E
BSOD may occur during RAID operations if volume name is 16 characters |
Win7, Win7-64, Windows Server 2008-64 |
|
3235277 |
Accelerated
RAID Volume: Clicking 'Disassociate' link pops-up Error message in UI after Acceleration
auto-transition from Enhanced to Off due to SSD being removed |
Win7, Win7-64 |
|
|
|||
Resolved Issues in 11.0.0.1015 Alpha |
|
||
Reference No |
Description |
Affected OS's |
|
3007123 |
Clear and Reset disk to normal in user interface
may not work |
Vista,Vista-64,Win7,Win7-64,Windows 2008,Windows
2008-64 |
|
3234888 |
When 2 RAID Volumes are present on
a system and left idle for a long time will cause IO fail |
N/A |
|
3235087 |
0x7E BSOD sporadically seen when RAID member
disk is hot removed during migration |
Win7-64 |
|
Known Issues
Known Issues in 11.0.0.1024 Beta |
|
||
Reference No |
Description |
Affected OS's |
|
3235475 |
System
does not reconstruct metadata after a S3 performed from windows that may lead
to OS corruption |
Win7,Win7-64 |
|
3235998 |
When
trying to enable acceleration, the disk selection screen shows full disk
capacity, max 64 GB for the cache which is not true all the time |
Win7,Win7-64 |
|
3235487 |
SUT
shows unknown icon in the taskbar during the installation of RST |
Win7,Win7-64 |
|
3235412 |
"Disk
data cache" resets to "enable" after resuming from S4/S5 in
RST UI |
Win7,Win7-64 |
|
3235655 |
After
using Sysprep, the system is no longer able to boot
when Smart Response Technology is enabled |
Win7-64 |
|
3235719 |
Significant
read performance degradation seen on 2-drive RAID1 to a 2-drive RAID0
migration due to Coalescer being disabled and not
re-enabled |
Win7-64 |
|
3235067 |
Smart
Response Technology is not honoring the user’s power plan |
Win7-64 |
|
3235083 |
0x50
BSOD sporadically seen after disconnecting cache volume from system |
Win7-64 |
|
3005451 |
Accessibility issue - Incorrect font size in high
contrast settings for Help |
Vista,Win7,Windows XP |
|
3006373 |
Tray icon disappears prematurely |
Vista,Vista-64,Win7,Win7-64,Windows 2003,Windows 2003-64,Windows
2008,Windows 2008-64,Windows Media Center, Windows XP, Windows XP-64 |
|
3006972 |
Reset cache SSD to passthru
appears to work, but doesn't when writes are failed to SSD |
Win7-64 |
|
3007006 |
RAID migration does not fail after drive sends
Status Err 0x40 |
Windows 2008 |
|
3007203 |
OS SMART Enable command to RAID volume not being
sent to member disks |
Win7 |
|
3006031 |
Error Injection causes non-NCQ
data verification failure |
Win7 |
|
3007165 |
0x9F BSOD sporadically seen when
running reboot/suspend stress test on ICH10 platforms |
Win7 |
|
3235279 |
Accelerated
pass-through data disk: Error message pop-up in UI when trying to use a
different SSD to Accelerate the disk after auto-transition Enhanced mode to
OFF due to missing Cache SSD |
Win7,Win7-64 |
|
3235185 |
Activate
Port x LED, doesn't work if SATA disk drives ports are not in sequential
order. |
Win7 |
|
3235555 |
Acceleration
is getting disabled while changing a specific SSD from one port to another
port in S3 |
Win7-64 |
|
3235466 |
Maximized
Accelerated disk/volume is not enumerated as Accelerated by the RST driver
after the OS doesn't shutdown cleanly |
Win7-64 |
|
3234671 |
Smart
Response Technology data mis-compare after 235
dirty shutdowns |
Vista-64 |
|
3235978 |
RST
UI warning message not sufficient when disabling acceleration and then
re-enabling |
Win7-64 |
|
3235807 |
Failed
caching SSD does not fail accelerated volume; volume stays in maximized mode |
||
3235310 |
Trying
to unlock a drive that is part of an accelerated volume causes the UI/OS to
freeze |
Win7 |
|
3235980 |
UI
requires two attempts to complete Acceleration action after Cache SSD removed
and replaced in Enhanced mode. Error message pops up when trying to
Accelerate with different SSD. |
Win7-64 |
|